1.
J Diabetes Complications ; 29(1): 93-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25264232

RESUMO

BACKGROUND: In bi-hormonal closed-loop systems for treatment of diabetes, glucagon sometimes fails to prevent hypoglycemia. We evaluated glucagon responses during several closed-loop studies to determine factors, such as gain factors, responsible for glucagon success and failure. METHODS: We extracted data from four closed-loop studies, examining blood glucose excursions over the 50min after each glucagon dose and defining hypoglycemic failure as glucose values<60 mg/dl. Secondly, we evaluated hyperglycemic excursions within the same period, where glucose was>180 mg/dl. We evaluated several factors for association with rates of hypoglycemic failure or hyperglycemic excursion. These factors included age, weight, HbA1c, duration of diabetes, gender, automation of glucagon delivery, glucagon dose, proportional and derivative errors (PE and DE), insulin on board (IOB), night vs. day delivery, and point sensor accuracy. RESULTS: We analyzed a total of 251 glucagon deliveries during 59 closed-loop experiments performed on 48 subjects. Glucagon successfully maintained glucose within target (60-180 mg/dl) in 195 (78%) of instances with 40 (16%) hypoglycemic failures and 16 (6%) hyperglycemic excursions. A multivariate logistic regression model identified PE (p<0.001), DE (p<0.001), and IOB (p<0.001) as significant determinants of success in terms of avoiding hypoglycemia. Using a model of glucagon absorption and action, simulations suggested that the success rate for glucagon would be improved by giving an additional 0.8µg/kg. CONCLUSION: We conclude that glucagon fails to prevent hypoglycemia when it is given at a low glucose threshold and when glucose is falling steeply. We also confirm that high IOB significantly increases the risk for glucagon failures. Tuning of glucagon subsystem parameters may help reduce this risk.


Assuntos
Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucagon/administração & dosagem , Bombas de Infusão Implantáveis , Adulto , Automação , Peso Corporal , Estudos de Coortes , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/fisiopatologia , Relação Dose-Resposta a Droga , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Glucagon/efeitos adversos , Humanos , Hiperglicemia/prevenção & controle , Hipoglicemia/prevenção & controle , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Resultado do Tratamento
2.
Diabetes Obes Metab ; 15(12): 1065-70, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23602044

RESUMO

Since the discovery of insulin, great progress has been made to improve the accuracy and safety of automated insulin delivery systems to help patients with type 1 diabetes achieve their treatment goals without causing hypoglycaemia. In recent years, bioengineering technology has greatly advanced diabetes management, with the development of blood glucose meters, continuous glucose monitors, insulin pumps and control systems for automatic delivery of one or more hormones. New insulin analogues have improved subcutaneous absorption characteristics, but do not completely eliminate the risk of hypoglycaemia. Insulin effect is counteracted by glucagon in non-diabetic individuals, while glucagon secretion in those with type 1 diabetes is impaired. The use of glucagon in the artificial pancreas is therefore a logical and feasible option for preventing and treating hypoglycaemia. However, commercially available glucagon is not stable in aqueous solution for long periods, forming potentially cytotoxic fibrils that aggregate quickly. Therefore, a more stable formulation of glucagon is needed for long-term use and storage in a bi-hormonal pump. In addition, a model of glucagon action in type 1 diabetes is lacking, further limiting the inclusion of glucagon into systems employing model-assisted control. As a result, although several investigators have been working to help develop bi-hormonal systems for patients with type 1 diabetes, most continue to utilize single hormone systems employing only insulin. This article seeks to focus on the attributes of glucagon and its use in bi-hormonal systems.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucagon/administração & dosagem , Hipoglicemiantes/administração & dosagem , Insulinas/administração & dosagem , Pâncreas Artificial , Glicemia/metabolismo , Previsões , Humanos , Hiperglicemia/prevenção & controle , Hipoglicemia/prevenção & controle
SELEÇÃO DE REFERÊNCIAS